Z Corporation Z406 System User Manual
104 Z Corporation Service (781)852-5050/(877)88-ZCORP
2. Depowder the part and the fixture.
3. Remove part from build plate and place on a clean surface. Then separate the part
from the fixture.
4. Apply a silicone mold release (such as IMS Paintable Neutral Oil Mold Release –
www.imscompany.com
or Hapco GREASE-IT FDG - www.hapcoweb.com) liberally
onto the top surface of the fixture where the part will make contact with the fixture.
This is done to prevent the infiltrated part from adhering to the fixture during the
infiltration process.
5. Gently apply Z-Snap or Z-Max epoxy to the bottom surface of the part and carefully
place the part back onto the fixture.
6. Apply Z-Snap or Z-Max epoxy to the rest of the part. Do not apply excess epoxy as
pooling will occur. Several thin coats are better than one thick coat.
Use a paper
towel or tissue paper to remove excess epoxy that may have pooled on the surface
of the part.